Bradford Equipment Inc.
UFDY.com

New & Used Foundry Equipment & Machinery On-line!

TRANSFORMERS & SUBSTATIONS Click to enlarge
New & Used Equipment
REF.
DESCRIPTION
EMAIL
PHOTO
(BRD10053) LARGE QTY OF UNIT SUBSTATION TRANSFORMERS
ranging from 1,000 through 2,500 KVA, 4,160 / 480 volts, 3 Phase 60 Hertz both Wye and Delta connected.  Both high and low voltage switch gear available for each unit     PHOTO
More Information 10053
(BRD10054)

COMPLETE SUBSTATION WITH TRANSFORMERS & SWITCH GEAR
46.0KV / 4,160 Y and Delta, 3 Phase, 60 Hertz.  Complete with three (3) 10.0 / 12.5, 11.2, 14.0 MVA transformers and switch gear.  Call for compelte details.

More Information 10054.
(BRD10000) ABB ELECTRICAL SUBSTATION
132.0 KV / 13.2 KV, 3 Phase, 60 Hertz, 24.0 / 32.0 / 40.0 MVA 55.0 Degree C, 26.8, 35.4, 44.8 MVA 65.0 Degree C, 3 Phase 60 Hertz. 1991 Vintage. Towers, High Voltage Switch Gear and other auxilary equipment available.
PHOTO      PHOTO      PHOTO      PHOTO      PHOTO
More Information 10000
(BRD10035) ABB Chandler Substation Transformer
55.0 / 74.6 / 93.3 MVA Class OA /FA /EA 230.0 KV/ 13.8 KV / 6,300 volts, 3 Phase 60 Hertz.
Primary taps of 235,750, 230,000, 222,500 and 218,500 volts
Late model unit with Copper Windings
PHOTO      PHOTO
More Information 10035
(BRD10034) ABB MILLHAVEN Substation Transformer
10.0 / 13.3 MVA, 55.0 / 65.0 Degree C Rise,
10.0 / 13.3 MVA. 3 Phase, 60 Hertz .
Primary taps 120,750, 117875, 115000, 112,125, 109,250 volts taps. Late model unit     PHOTO
More Information 10034
(BRD10024) ALLIS CHALMERS SUBSTATION TRANSFORMER
1,500 KVA, 3 Phase, 60 Hertz,
Class OA/FFA Substation Transformer.
69.0 KV/4,360 Y / 2,520 Volts.
Primary Taps 70,600, 68,800, 67,000, 65,200 and 63,400 Volts.
More Information 10024
(BRD9983) COOPER Distribution Transformer
1000 KVA Class OA/FA 55/65 Degree C Rise, 12,470 Volts Delat /480/277 Volts YU.
PHOTO
      PHOTO      PHOTO
More Information 9980
(BRD10033) FERRANTI PACKARD Step Down Transformer
25.0/33.3/41.6 MVA 65 Degree C Rise,
138 KV WYE / 7,967 / 6,600 WYE / 3,810 volts,
3 Phase, 60 Hertz
Late model, excellent condition with short in service time
Quantity of two (2) available
More Information 10033

(BRD10030)
(BRD10031)

GEC Alsthem 3,275 / 4094 KVA, 13.8 KV Delta
/ 575 Volts Delta, 3 Phase, 60 Hertz Step down transformer for induction furnace power supply.
GEC Alsthem 3,275 / 4094 KVA, 13.8 KV Delta / 575 Volts Wye, 3 Phase , 60 Hertz Step down transformer for induction furnace power supply.
Primary voltage taps of 14,490, 14,145, 13,800, 13,455 and 13,110 volts on both units.
Test data available along with service records.
PHOTO   PHOTO   PHOTO   PHOTO
PHOTO   PHOTO   PHOTO
More Information 10030
(BRD10016) GENERAL ELECTRIC INDUCTION FURNACE POWER SUPPLY TRANSFORMER
2,000 KVA, 12,470 / 575 volts Delta, 3 Phase, 60, Hertz.
High voltage taps 13,090, 12,780, 12,470, 12,160, and 11,850 volts.
Total weight 14,200 pounds, tank 3,800 pounds, oil 3,400 pounds, core and coils 7,000.
PHOTO   PHOTO   PHOTO
More Information 10016
(BRD10047) DISTRIBUTION TRANSFORMERS Quantity of two (2) with 1,600 amp  480 volt 3 phase circuit breakers
12,470 Delta / 480 Wye / 277 volt
Additional low voltage breakers are available with outdoor enclosure       SOLD
PHOTO  PHOTO  PHOTO  PHOTO  PHOTO
More Information 10047
(BRD10004) GE DISTRIBUTION TRANSFORMERS
2,240 KVA Class OA, 4,160 volts Delta / 480 volts Wye / 277 volts 3 Phase, 60 Hertz.
3,360 KVA Class OA, 4,160 volts Delta / 480 volts Wye / 277 volts 3 Phase, 60 Hertz.
1,680 KVA Class OA 4,160 volts Delta / 480 volt Wye / 277 volts 3 Phase, 60 Hertz.
High and Low Voltage switch gear available with these units.     PHOTO
More Information 10004
(BRD10005) GE DISTRIBUTION TRANSFORMER
GENERAL ELECTRIC 500 KVA
, Class OA, 2,400 Volts Delta / 480 volts Wye / 277 volts 3 Phase, 60 Hertz.
High and Low Voltage Breakers available as well as other auxilary equipment.     PHOTO
More Information 10005
(BRD10003) GE DISTRIBUTION TRANSFORMERS
Wide variety to choose from
General Electric 13.2 KV Delta / 480 Volts Wye / 277 Volts, 3 Phase 60 Hertz, 2,500, 2,800 KVA 55 / 65 Degrees C Class OA / FA. 6.0 % impedance Silicon Filled. Already equipped with fan cooling. Quantity of five (5) available.
General electric 13.2 KV Delta / 480 Volts Wye /277 Volts 3 Phase, 60 Hertz. Total of five (5) units ranging from 1,000 KVA up to 1,500 KVA.
High and low voltage switch gear as well as other auxilary equipment available.
PHOTO      PHOTO      PHOTO      PHOTO
PHOTO        PHOTO    PHOTO    PHOTO
PHOTO      PHOTO PHOTO 

More Information

10003

10003

(BRD9980) GENERAL ELECTRIC Distribution Transformer
1,000 KVA, Class OA 12,470Y /480 volts Delta.
Total Weight7,800 Pounds, Core & Coil 3,200 Pounds,
Tank & Fittings 2,200 Pounds,
Fluid 2,200 Pounds (300 gallons) PHOTO      PHOTO
More Information 9980
(BRD9908) GE ELECTRIC ARC FURNACE TRANSFORMER
7.5/7.9 MVA. Four position motorized off load tap changer, Delta / Wye switch. Just removed from service, replaced in an upgrade.

PHOTO      PHOTO      PHOTO      PHOTO
Detailed Specs [pdf]
BRD9908
(BRD10016) GENERAL ELECTRIC INDUCTION FURNACE POWER SUPPLY TRANSFORMER
2,000 KVA, 12,470 / 5765 volts Delta, 3 Phase, 60, Hertz.
High voltage taps 13,090, 12,780, 12,470, 12,160, and 11,850 volts.
Total weight 14,200 pounds, tank 3,800 pounds, oil 3,400 pounds, core and coils 7,000.
PHOTO   PHOTO   PHOTO
More Information 10016
(BRD10043) KITAHIBA ELECTRIC ARC FURNACE TRANSFORMER SPECS [pdf]
20,000 / 22,400 KVA, 55.0 / 65.0 Degree C rise,
20.0 KV / 365 Volts, 3 Phase, 50 Hertz.
Secondary voltage taps 365, 345, 325, 307, 285, 265 Delta, 211, 199, 188, 177, 165, 133 Wye.
Maximum secondary current 35,500 amps.
Four position motorized off load tap changer
More Information 10043
(BRD10032) Megatran 46.0 KV / 4,160 Volts, 3 Phase, 60 Hertz, 18.0 / 24.0 MVA, Class ONAN / ONAF step down transformer.
New in 2001. Installed and never placed into service
Quantity of two (2) available.
More Information 10032
(BRD9920) MCGRAW EDISON ARC FURNACE TRANSFORMER
8 / 8.9 MVA. Four position motorized off load tap changer, Delta / Wye switch.

PHOTO  PHOTO  PHOTO  PHOTO  PHOTO  PHOTO
Detailed Specs [pdf]
More Information BRD9920
(X9P2990)

PACIFIC CREST TRANSFORMER
S/N : PMD-0192
TYPE PADMOUNT
875 KVA, 3 PH, 60 HZ
HIGH VOLTAGE: 25 000 DELTA
See PDF spec sheet

More Information 2990
(BRD10037) PENNSYLVANIA 1,500 / 1680 KVA Class OW,
55 / 65 degree C rise, 3 Phase, 60 Hertz
Electric Arc Furnace Transformer.
Serial Number 37600-1.
4160 volts / 215 volts.
Motorized off load four (4) position tap changer.
Excellent documented history
PHOTO    PHOTO    PHOTO    PHOTO
More Information 10037
(BRD10001) PORTER ELECTRIC SUBSTATION
67.0 KV / 2,400 Volts 3 Phase, 60 Hertz, 5,000 KVA 55 Degree C, Class OA.
67.0 KV / 13.8 KV, 3 Phase, 60 Hertz, 5,000 KVA, 55 Degree C, Class OA. 1999 vintage.
High voltage and auxilary equipment available also.
PHOTO      PHOTO      PHOTO      PHOTO
More Information 10001
(BRD10002) ELECTRICAL SUBSTATION - WAUSHEKA ELECTRIC TRANSFORMERS
10.0/12.5/14.0 MVA, Class OA/FA, 138.0 KV Delta / 4,160 Volts Wye / 2,450 volts, 3 Phase, 60 Hertz. Includes transformer, towers, regulating transformers, switch gear, harmonic filter bank, switch gear and additional auxilary equipment. This substation was new in 1999 and is now surplus to operation.
PHOTO      PHOTO      PHOTO      PHOTO      PHOTO
PHOTO        PHOTO    PHOTO   PHOTO      PHOTO
PHOTO      PHOTO PHOTO
More Information

10002

10002

(BRD10052)

WESTINGHOUSE SUBSTATION TRANSFORMER
11.4 KV  2,650 volts Y, 4,630 KVA Type SL, Class A, 55.0 Degree C Rise
Serial No. SNR32121.  Impedance 5.9%.  Primary taps of 11,970, 11,685, 11,400, 11,115, and 10,830 volts.

More Information 10052
(BRD9981) WESTINGHOUSE 500 KVA Class OA Step Down Transformer.
7200 Volts/12470Y / 240 x 480 volts
5,200 pounds total weight, 2,400 pounds core and coil,
1,650 pounds oil. Immpedance 5.5%.
PHOTO      PHOTO      PHOTO
More Information 9981
(BRD9990)

WESTINGHOUSE Electric Arc Furnace Transformer
5.0 /  MVA, 55 / 65 degree C rise, Class FOW, 13,090 Volts / Volts 3 Phase,   Hertz.  Transformer has a four (4) position off load motorized transfer switch and Delta / Wye switch.  Unit is certified PCB free.  Maintenance and testing reports available. 
PHOTO      PHOTO

More Information 9990
(BRD9905)
(BRD9906)
(BRD9907)

WESTINGHOUSE ELECTRIC ARC FURNACE TRANSFORMERS (3 available)
12.0/13.44 MVA. Six position motorized off load tap changer, Delta / Wye switch. Just removed from service, replaced in an upgrade.

Detailed Specs [pdf]

BRD9905
(XB1843)
(XB1844)
(XB1845)

TRANSFORMER, PHASE BALANCING REACTOR (3 AVAILABLE) HUNTER DON
(1)200 KVAR, (2)600 KVAR   PHOTO   PHOTO

More Information
 

LARGE INVENTORY OF SUBSTATION AND STEP DOWN TRANSFORMERS AVAILABLE.

  • H.K. Porter 6,000 KVA, 55.0 Degree C, 13.8 KV/ 4,160Y / 2400, 3 Phase, 60 Hertz.
  • Allis Chalmers 6,000 KVA, 55.0 Degree C, 13.8KV/ 4,160Y / 2,400, 3 Phase, 60 Hertz.
  • Wide variety of 12,470 / 480 Volts and 4,160 / 480 Volts transformers both oil filled and dry type. 

Many of these are equipted with circuit breakers.
Contact us for complete inventory and availability.   

More Information  

Home

Transformers, Arc Furnace Transformers Electric Arc Furnace Transformers, EAF Transformers, McGraw Edison, Westinghouse, GE Transformers, EAF Transformers, HK Porter, Used Foundry Equipment, Used Foundry Machines, New Foundry Equipment and Foundry Machines from Bradford Equipment Inc.

Updated October 6, 2014
This site is Copyrighted 1997-2012 by BRADFORD EQUIPMENT INC. All Rights Reserved.
No part of this site may be copied or reproduced without the expressed written consent of BRADFORD EQUIPMENT INC.